Robotic sperm

From LIMSWiki
Revision as of 17:31, 23 February 2016 by Admin (talk | contribs) (Transcluded, per John)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Robotic sperm (also called spermbots) are biohybrid microrobots consisting of sperm cells and artificial microstructures.[1][2][3] Currently there are two types of spermbots. The first type, the tubular spermbot, consists of a single sperm cell that is captured inside a microtube. Single bull sperm cells enter these microtubes and become trapped inside. The tail of the sperm is the driving force for the microtube.[1] The second type, the helical spermbot, is a small helix structure which captures and transports single immotile sperm cells. In this case, a rotating magnetic field drives the helix in a screw-like motion. Both kinds of spermbots can be guided by weak magnetic fields.[2] These two spermbot designs are hybrid microdevices, they consist of a living cell combined with synthetic attachments. Other approaches exist to create purely synthetic microdevices inspired by the swimming of natural sperm cells, i.e. with a biomimetic design, for example so-called Magnetosperm which are made of a flexible polymeric structure coated with a magnetic layer and can be actuated by a magnetic field.[4]

Design

Tubular spermbots

Initially, the microtubes for the tubular spermbots were made using roll-up nanotechnology on photoresist.[5] In this process, thin films of titanium and iron were deposited onto a sacrificial layer. When the sacrificial layer was removed, the thin films rolled into 50 μm long microtubes with a diameter of 5 - 8 μm. Later on, the microtubes were made from a temperature-responsive polymer to enable the controlled release of the sperm cells upon a small temperature change of a few degrees.[6]

Tubular spermbots are assembled by adding a large amount of the microtubes to a diluted sperm sample under the microscope. The sperm cells randomly enter the microtubes and become trapped in their slightly conical cavity. In order to increase the coupling efficiency between sperm cells and microtubes, the microtubes have been functionalized with proteins or sperm chemoattractant. This has been done using thiol chemistry once the tubes are rolled-up or by transferring the molecules with an elastomer stamp onto the material before rolling the tubes.[7]

Helical spermbots

Helical spermbots are assembled by driving a magnetic microhelix over an individual sperm cell, thereby confining its tail inside the helix lumen and pushing the head of the sperm forward. The sperm cell is loosely coupled to the helix and can be released by reversing the rotation of the helix, letting it withdraw from the head and free the confined tail in the process. Such microhelices were fabricated by direct laser lithography and coated with nickel or iron for magnetization.[2]

Robotic sperm can be navigated by weak external magnetic fields of a few mT. These fields can be generated by permanent magnets or by a setup of electromagnets. The applied magnetic field can be a homogeneous, rotating, or gradient field.[8] Tubular and helical spermbots can also be navigated in a closed-loop control scheme with an electromagnetic coil setup.[9]

Applications

Spermbots hold promise for potential application in single cell manipulation and assisted reproduction, but also for targeted drug delivery. A recent study shows that modified tubular spermbots can be used for delivery of cancer drugs.[10] In this case, the sperm cell is loaded with doxorubicin. The artificial microstructure fabricated by two-photon nanolithography captures the drug-loaded sperm cell. The sperm cell is the actuation source for the magnetic microstructure and can propel it to cancer spheroids. At this location, the drug-loaded sperm is released by a spring mechanism and the sperm cell delivers the drug to the cancer cells.

Perspectives

Robotic sperms as microswimmers are interesting for diverse biomedical applications, specifically for new assisted fertilization techniques and for the targeted delivery of therapeutic cargo. These microswimmers are meant to operate in in vivo environments, a feature that may revolutionize assisted reproduction technologies and nanomedicine in the future.[11] New designs are emerging and plenty of applications can be derived from the here reported concept.[3][11]

References

  1. ^ a b Magdanz, Veronika; Sanchez, Samuel; Schmidt, Oliver G. (2013). "Development of a Sperm-Flagella Driven Micro-Bio-Robot". Advanced Materials. 25 (45): 6581–6588. doi:10.1002/adma.201302544. PMID 23996782.
  2. ^ a b c Medina-Sánchez, Mariana; Schwarz, Lukas; Meyer, Anne K.; Hebenstreit, Franziska; Schmidt, Oliver G. (2016). "Cellular Cargo Delivery: Toward Assisted Fertilization by Sperm-Carrying Micromotors". Nano Letters. 16 (1): 555–561. Bibcode:2016NanoL..16..555M. doi:10.1021/acs.nanolett.5b04221. PMID 26699202.
  3. ^ a b Magdanz, Veronika; Medina-Sánchez, Mariana; Schwarz, Lukas; Xu, Haifeng; Elgeti, Jens; Schmidt, Oliver G. (2017). "Spermatozoa as Functional Components of Robotic Microswimmers". Advanced Materials. 29 (24): 1606301. doi:10.1002/adma.201606301. PMID 28323360.
  4. ^ Khalil, Islam S. M.; Dijkslag, Herman C.; Abelmann, Leon; Misra, Sarthak (2014). "MagnetoSperm: A microrobot that navigates using weak magnetic fields". Applied Physics Letters. 104 (22): 223701. Bibcode:2014ApPhL.104v3701K. doi:10.1063/1.4880035.
  5. ^ Mei, Yongfeng; Huang, Gaoshan; Solovev, Alexander A.; Bermúdez Ureña, Esteban (2008). "Versatile Approach for Integrative and Functionalized Tubes by Strain Engineering of Nanomembranes on Polymers". Advanced Materials. 20 (21): 4085–4090. doi:10.1002/adma.200801589.
  6. ^ Magdanz, Veronika; Guix, Maria; Hebenstreit, Franziska; Schmidt, Oliver G. (2016). "Dynamic Polymeric Microtubes for the Remote-Controlled Capture, Guidance, and Release of Sperm Cells". Advanced Materials. 28 (21): 4084–4089. doi:10.1002/adma.201505487. PMID 27003908.
  7. ^ Magdanz, Veronika; Medina-Sánchez, Mariana; Chen, Yan; Guix, Maria; Schmidt, Oliver G. (2015). "How to Improve Spermbot Performance". Advanced Functional Materials. 25 (18): 2763–2770. doi:10.1002/adfm.201500015.
  8. ^ Zhang, Li; Abbott, Jake J.; Dong, Lixing; Kratochvil, Bradley E.; Bell, Dominik; Nelson, Bradley J. (2009). "Artificial bacterial flagella: Fabrication and magnetic control". Applied Physics Letters. 94 (6): 064107. Bibcode:2009ApPhL..94f4107Z. doi:10.1063/1.3079655.
  9. ^ Khalil, Islam S. M.; Magdanz, Veronika; Sanchez, Samuel; Schmidt, Oliver G.; Misra, Sarthak (2013). "Three-dimensional closed-loop control of self-propelled microjets". Applied Physics Letters. 103 (17): 172404. Bibcode:2013ApPhL.103q2404K. doi:10.1063/1.4826141.
  10. ^ Xu, Haifeng; Medina-Sánchez, Mariana; Magdanz, Veronika; Schwarz, Lukas; Hebenstreit, Franziska; Schmidt, Oliver G. (2017). "Sperm-hybrid micromotor for drug delivery in the female reproductive tract". ACS Nano. 12 (1): 327–337. arXiv:1703.08510. doi:10.1021/acsnano.7b06398. PMID 29202221.
  11. ^ a b Medina-Sánchez, Mariana; Schmidt, Oliver G. (2017). "Medical microbots need better imaging and control". Nature. 545 (7655): 406–408. Bibcode:2017Natur.545..406M. doi:10.1038/545406a. PMID 28541344.

Notes

This article is a direct transclusion of the Wikipedia article and therefore may not meet the same editing standards as LIMSwiki.