Difference between revisions of "File:Fig3 Pickering LancetMicrobe2021 2-9.jpg"

From LIMSWiki
Jump to navigationJump to search
 
(Added summary.)
Line 1: Line 1:
==Summary==
{{Information
|Description='''Figure 3.''' Comparative evaluation of antigen test sensitivity for the B.1.1.7 variant versus non-B.1.1.7 variant. Combined nasopharyngeal swabs were obtained from 23 individuals with confirmed SARS-CoV-2 B.1.1.7 infection (December 2020 through January 2021) and compared with samples from before the variant was widely circulating in the U.K. population (April through September 2020). All swabs were matched for N Ct values, shown in ascending order in the graph, and tested on Innova and SureScreen-V rapid antigen tests. N = SARS-CoV-2 nucleocapsid; Ct = cycle threshold; SureScreen-V = SureScreen visual.
|Source={{cite journal |title=Comparative performance of SARS-CoV-2 lateral flow antigen tests and association with detection of infectious virus in clinical specimens: A single-centre laboratory evaluation study |journal=The Lancet Microbe |author=Pickering, S.; Batra, R.; Merrick, B. et al. |volume=2 |issue=9 |pages=e461-e471 |year=2021 |doi=10.1016/S2666-5247(21)00143-9}}
|Author=Pickering, S.; Batra, R.; Merrick, B. et al.
|Date=2021
|Permission=[http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International]
}}


== Licensing ==
== Licensing ==
{{cc-by-4.0}}
{{cc-by-4.0}}

Revision as of 18:18, 22 September 2021

Summary

Description

Figure 3. Comparative evaluation of antigen test sensitivity for the B.1.1.7 variant versus non-B.1.1.7 variant. Combined nasopharyngeal swabs were obtained from 23 individuals with confirmed SARS-CoV-2 B.1.1.7 infection (December 2020 through January 2021) and compared with samples from before the variant was widely circulating in the U.K. population (April through September 2020). All swabs were matched for N Ct values, shown in ascending order in the graph, and tested on Innova and SureScreen-V rapid antigen tests. N = SARS-CoV-2 nucleocapsid; Ct = cycle threshold; SureScreen-V = SureScreen visual.

Source

Pickering, S.; Batra, R.; Merrick, B. et al. (2021). "Comparative performance of SARS-CoV-2 lateral flow antigen tests and association with detection of infectious virus in clinical specimens: A single-centre laboratory evaluation study". The Lancet Microbe 2 (9): e461-e471. doi:10.1016/S2666-5247(21)00143-9. 

Date

2021

Author

Pickering, S.; Batra, R.; Merrick, B. et al.

Permission
(Reusing this file)

Creative Commons Attribution 4.0 International

Other versions


Licensing

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current18:15, 22 September 2021Thumbnail for version as of 18:15, 22 September 2021647 × 518 (48 KB)Shawndouglas (talk | contribs)